Attachment for femur sliding screw plate

Attachment for femur sliding screw plate Manufacturer, Exporter & Supplier

  • MIO - Sliding hip screw with plate

    Detailed step by step description of MIO - Sliding hip screw with plate for - Trochanteric fracture, pertrochanteric, multifragmentary located in our module on Proximal femur with illustrations including patient positioning, approach and aftercare. The correct screw is ...

  • Attachment for femur sliding screw plate - Hospital, For

    27/11/1990· A femur sliding screw plate is improved by adding flanges or wings on either side of a central portion, the flanges extending at least partially around the femur shaft. Preferrably, the flanges are pr What I claim is: 1. An attachment for a femur screw plate, said femur ...

  • Locking Attachment Plate. For treatment of periprosthetic fractures.

    Locking Attachment Plate. For treatment of periprosthetic fractures. Surgical Technique This publication is not intended for distribution in the USA. Locking Attachment Plate Surgical Technique DePuy Synthes 1Introduction Surgical Technique Product Information ...

  • US4612920A - Compression hip screw - Google Patents

    A compression hip screw for fixation of a femoral head in a femur bone, the compression hip screw comprising a plate adapted for attachment to the femur, the plate leading superiorly to a barrel extending into an opening, the opening being provided on the femur

  • Intramedullary Nail Versus Dynamic Hip Screw;

    These types are not well controlled by the sliding compression hip screw and side plate and are associated with a high rate of fixation failure when treated with dynamic hip screw. Theoretical biomechanical advantages of intramedullary nails over screw and

  • NCB® Periprosthetic Femur Plate System Surgical Technique

    NCB ® Periprosthetic F Syst Surgical Technique 5 The labeling of the NCB Periprosthetic Proximal and Distal Femur Plates corre-sponds with number of NCB Plate holes in a specific way. Proximal Plates: the number of holes according label text = the number of

  • Fixation of Intertrochanteric Fractures: Dynamic Hip

    Fixation of Intertrochanteric Fractures: Dynamic Hip Screw versus Locking Compression Plate Mohsen Mardani-Kivi 1 , Ahmadreza Mirbolook 1, * , Sina Khajeh Jahromi 2 , Melina Rouhi Rad 2

  • Proximal femur - Approach - AO Surgery Reference

    The lateral approach is used for insertion of a sliding hip screw or multiple screws after closed reduction of a proximal femoral fracture. The incision can be extended proximally to accommodate a trochanteric stabilizing plate.

  • A Comparison of the Long Gamma Nail with the Sliding Hip Screw for the Treatment of AO/OTA 31-A2 Fractures of the Proximal Part of the Femur

    A Comparison of the Long Gamma Nail with the Sliding Hip Screw for the Treatment of AO/OTA 31-A2 Fractures of the Proximal Part of the Femur A Prospective Randomized Trial By Tristan M. Barton, MBChB, MSc, Robert Gleeson, FRCS(Orth), Claire Topliss

  • Ax SOS Locking Plate System - Home - ZWAN

    for screw attachment or fixation to the posterior elements (pedicles) of the cervical, thoracic or lumbar spine. 4 5 OperativeTechnique ... plate positioning and sliding of longer plates sub-muscularly (Fig. 3). Fig. 3 OperativeTechnique Step2bIntr a Operative ...

  • Femur Omeg a3 System 95˚ Supracondylar Plate

    3 Potential Features & Benefits Introduction The 95 plate angle design of the Omega3 Supracondylar Plate contours to the anatomy of the distal femur including the flare of the lateral femoral condyle. This assures more precise component fit and function with

  • Proximal Femur Fractures - by Jeffrey Shyu, MD

    14/1/2015· Proximal Femur Fractures - by Jeffrey Shyu, MD 1. Proximal Femur Fractures Jeffrey Shyu, MD 2. Learning Objectives Provide an intuitive understanding of the morphologic types, injury mechanisms, and classification systems of adult proximal femur ...

  • Is a Sliding Hip Screw or IM Nail the Preferred Implant

    9/5/2008· The cohort consisted of 43,659 patients. Patients treated with an intramedullary nail had higher rates of revision surgery during the first year than those treated with a sliding hip screw (7.2% intramedullary nail versus 5.5% sliding hip screw).

  • Treatment of intertrochanteric fracture of the femur

    Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation. Wolfgang GL, Bryant MH, O'Neill JP. Sliding screw plate fixation of intertrochanteric fractures of the femur is not always a simple operation with universally excellent results.

  • Femoral Fractures - Physiopedia

    A femoral fracture is a fracture of the femur (thigh bone). A femoral shaft fracture is defined as a fracture of the diaphysis occurring between 5 cm distal to the lesser trochanter and 5 cm proximal to the adductor tubercle occurs by chronic, repetitive activity that is common to runners and military. These injuries must be differentiated from insufficiency fractures, which, though similar in ...

  • Surgical Technique - Smith & Nephew - Corporate

    4 Indications IMHS CP Intramedullary Hip Screw is indicated for fractures of the proximal femur including peritrochanteric fractures, reverse obliquity fractures, and subtrochanteric fractures. The long nails expand indications to include comminuted neck and shaft

  • DHS Locking Plate - YouTube

    3/12/2015· DHS/DCS Lag Screw. DCP® (Dynamic Compression Plate) holes in the DHS side plate: allow angulation of 4.5 mm Cortex Screws and locking option for 5.0mm Cortex Locked screws, for lag screw ...

  • Femur AxSOS KnifeLight Targeting System Carpal Tunnel

    5 Features & Benefits System The Distal Lateral Femoral Plate is designed with optimized fixed-angled screw trajectories in the metaphyseal part and perpendicular fixed-angled screw trajectories in the diaphyseal part, which provide increased biome-chanical

  • The locking attachment plate for proximal fixation of

    27/5/2012· The locking attachment plate (LAP) (Synthes, Solothurn, Switzerland), a clamp-on plate attached to a conventional locking compression plate (LCP), provides lateral arms for bicortical offset screw placement beside the prosthesis stem.

  • DHS/DCS Dynamic Hip and Condylar Screw System TG

    2 Synthes DHS/DCS Dynamic Hip and Condylar Screw System Technique Guide The Dynamic Hip Screw is designed to provide strong and stable internal fixation of a variety of intertrochanteric, subtrochanteric and basilar neck fractures, with minimal soft tissue

  • MIO - Sliding hip screw - AO Foundation

    Detailed step by step description of MIO - Sliding hip screw for - Femoral neck fracture, subcapital, displaced located in our module on Proximal femur with illustrations including patient positioning, approach and aftercare. The first step is to position a guide wire on ...

  • Sliding Hip Screw / Dynamic Hip Screw Orthogate

    Sliding Hip Screw / Dynamic Hip Screw Paul Duffy, M.D., FRCSC Calgary, AB Intertrochanteric fractures in the elderly are very common and result in significant morbidity and mortality. Operative management has become the standard of care for these fractures ...

  • TFN-ADVANCED® Proximal Femoral Nailing System

    No available references for this product. Indication Statement TFN-Advanced Proximal Femoral Nailing System is intended for treatment of fractures in adults and adolescents (12-21) in which the growth plates have fused. Specifically, the system is indicated for ...

  • Dynamic Hip Screw Surgery Operation - DHS - YouTube

    16/10/2013· Once the hole is drilled, the surgeon inserts a lag screw into the hole and places a metal plate over the lag screw and against the femur. When the plate

  • For Treatment of Periprosthetic Fractures 3.5 mm Locking

    6 DePuy Synthes 3.5 mm Locking Attachment Plate Surgical Technique Preparation continued 3 Approach Make a straight incision on the lateral side of the femur, or two to three small incisions, depending on the reduction and plate insertion technique. 2

  • Attachment for femur sliding screw plate - Patent -

    A femur sliding screw plate is improved by adding flanges or wings on either side of a central portion, the flanges extending at least partially around the femur shaft. Preferrably, the flanges are provided integral to a centrally raised part which fits over a portion of the ...

  • A study of management of trochanteric fracture of femur

    25/4/2017· A study of management of trochanteric fracture of femur treated with dynamic sliding hip screw-plate device vs. proximal femoral nail Background: The incidence of intertrochanteric fractures has been increasing significantly due to the rising age of modern human populations.